[Company Logo Image]  

Home Up News Feedback Contents Search Technical Tips Links


Tremetrics VMAX


Home
Up
Audiometers
Audiometric Test Rooms
Electroacoustic Ears
Electrocardiographs
Noise Dosimeters
School Health
Services
Software
Sound Level Meters
Vision Testers

 

 

Now you can perform pulmonary function testing (PFT) at your facility using a proven "clinical quality" system. With the Tremetrics Vmax, you can select either a dry rolling seal spirometer or mass flow sensor spirometer -- the choice is yours!

Easy to use PC-based software allows the testing to be set up and viewed in real time with norms generated to fit each individual's vital capacity profile. Advanced features also provide continuous quality control monitoring and color coded flags appear when results do not meet current ATS standards.

You will appreciate Vmax's new report customization features. A "drag and drop" graphical report generator helps build custom reports with time/volume graphs scaled to size and your choice of information inserted automatically.

This proven system includes convenient computerized multimedia training modules so that technicians can become proficient in operating theVmax system as well as learn techniques that will encourage the best pulmonary function effort from the subject being tested.

Check the extra value features

  • On-line video and voice tutorials for getting the best subject effort on the test
  • Quick reports -- simply "drag and drop" color graphics and data items onto the page
  • Dry rolling seal or mass flow sensor spirometer -- the choice is yours!
  • Interfaces with FOSHM safety and health software
  • Based on proven system used in thousands of clinics and hospitals

Vmax Specifications

Specifications – Mass Flow*
Range: 0 - >16 LPS
Integrated Volume Range: 0 - 350 LPM
Resolution: 0.03 LPS
Accuracy: ± 3% of reading or 0.2 LPS,
(whichever is greater)
Flow Path Resistance: <1.5cm H2O/LPS at 12 LPS
Integrated Flow Accuracy: ± 0.05 Flow Direction Transducer (DIR)
Range: ± 2cm H2O
Mouth Pressure Transducer (PM)
Range: ± 400cm H2O
Accuracy: ± 1%
Barometric/Sample Pressure Transducer (BP)
Range: 300 - 800mm Hg
Accuracy: ± 3mm Hg
Temperature Sensor (TEMP)
Range: 0° - 40°C
Accuracy: ± 1°C
Control Module Environmental Requirements
Operating Temperature: 5° - 40°C
Operating Humidity: 15% - 95%
(non-condensing)
Storage Temperature: -20° - 50°C
Storage Humidity: 0% - 100% (non-condensing)
Control Module Dimensions
13"W x 14"D x 3.75"H (33cm x 36cm x 9.5cm)
Electrical Requirements
Power: 100 VAC to 240 VAC, 50/60 Hz
Phase: Single
Current: Maximum 15 Amp at 115 VAC
Leakage Current: <100 microamperes

Specifications – Volume Displacement*
Displacement Volume: Approximately 10 liters;
indicated optional chart drive volume is 8 liters
Dynamic Resistance: <1.0cm H2O/LPS at 12 LPS
Static Resistance: < 0.20cm of water
Volume to Displacement Transfer Factor: 670 mL/cm
Computer interface: Digital
Spirometer Dimensions
14"W x 14"D x 15"H (36cm x 36cm x 38cm);
depth with optional recorder, 24" (61cm)
Electrical Requirements
Power: 120 or 240 VAC, 50/60 Hz

*Complete PFT system includes computer, VMax software, flow
or volume displacement spirometer and printer.

 

 

 


Correspondence and orders can be sent to:                     LIPIN/DIETZ ASSOCIATES, INC. 

   100 WATER STREET 

    GUILFORD, CONNECTICUT 06437

TELEPHONE (203) 453-8888


 

Home ] Up ]

 

[ Home ] Audiometers ] Audiometric Test Rooms ] Electrocardiogrphs ] Noise Dosimeters ] Services ] Software ] Sound Level Meters ] Spirometers ] Vision Testers ]

Send mail to tdietz@lipindietz.com with questions or comments about this web site.
Copyright © 2001 Lipin/Dietz Associates, Inc.